Home  |  Contact Us  |  Site Map  |  Glossary  

 
 
     
 
 
 

8144 Clock Selector/Distribution Amplifier

Clock Selector/Distribution Amplifier - Model 8144

Clock Selector/Distribution Amplifier - Model 8144

  • Timing Failure Detection Automates Switchover to Backup Source
  • Double Input (Selector/Distribution Amplifier) or Single Input (Distribution Amplifier)
  • Twelve Distribution Outputs
  • User Configurable with Switch Parameters, Alarm Latching, Bridging of Inputs, DS1 Line Build Out, and DS1 Outputs D4 or ESF
  • 5-Year Warranty

Product Overview

The Spectracom Model 8144 Clock Selector / Distribution Amplifier detects failure of input clock and provides manual or automatic switchover between two clock sources. The selected input is distributed via twelve buffered output line drivers.


Technical Specifications

Clock Outputs Twelve individually buffered DS1 framed all ones, (optionally RS-485 or E1) derived from the selected input. DS1’s may be set for ESF or D4 framing and LBO to 655 feet.
Clock Inputs Two DS1’s, with D4 or ESF framing (optionally RS-485 or E1).
Selectable bridging or terminating input impedance.
Reference Switching Normally non-revertive, but may be set to give priority to Input Channel A. Switchover occurs with Loss of Signal (LOS) or Alarm Indication Signal (AIS) at the selected reference input; when an external alarm is sensed; or when manual selection is made.
Alarm Outputs Major and minor alarms activated by LOS, AIS, or external alarm input. Relay contacts SPDT, 2A @ 30 VDC.
External Alarm Inputs One for each input channel; grounding or RS-422/485 level activation. Activates switchover and alarm outputs.
Power 115/230 VAC ±15%, 50/60 Hz; 15 W (standard).
12 - 24 VDC Option: 11 to 32 VDC; 12 W.
48 VDC Option: 55.2 VDC ±20%; 12 W.

DC options provide dual fused inputs and reverse polarity protection.

Physical & Environmental

Size EIA 19" rack W x 3.5"H x 10"D
Weight 6 lbs. maximum
Connectors Clock I/O: Pluggable terminal strip
Alarm I/O: Pluggable terminal strip
AC power:3-prong connector, 7' cord included
DC power: Terminal strip
Switches Power, manual or automatic mode, manual input selection
Indicators Major & minor alarms, A & B input ready, A or B input selected
Temperature 0°to +60°C operating range
-40°C to +85 °C storage temperature
Humidity 95% R.H. non-condensing

Ordering Information

CONFIG INPUTS OUTPUTS
8144-DD DS1 DS1
8144-DR DS1 RS-422/485
8144-RD RS-422/485 DS1
8144-EE E1 E1
8144-ER E1 RS-422/485
8144-RE RS-422/485 E1
8144-RR RS-422/485 RS-422/485
Specify Model 8144, I/O configuration, and Option 11 for rack slides.
Option 52 for 12 - 24 VDC power.
Option 54 for 48 VDC power.
Example 8144-DD-11-54
DD - DS1 inputs and outputs
11 - Rack slides
54 - 48 VDC power input

 
 
   
 
  ©1995-2008 Spectracom Corp | Privacy Statement | Contact Us