8182 NetClock®/2 Master Clock
NetClock ® / 2 Master Clock - Model 8182

- Legally Traceable Time™ from Station WWVB
- Ideal for Synchronizing 9-1-1 Systems and Computer Networks
- Meets NENA PSAP Master Clock Standard
- Automatic Adjustment for Local Time, Daylight Saving Time and Year
- Accurate to Within 1 Millisecond of UTC
- Affordable
- 5-Year Warranty
Product Overview
The Spectracom NetClock/2 is the world standard in master clocks, and this model provides more features and capabilities than ever before, including full conformance with the new NENA 04-002 PSAP Master Clock Standard.
NetClock/2 receives legally traceable time signals from WWVB, the 60-kHz time and frequency standard radio station maintained by the U.S. National Institute of Standards and Technology (NIST). These signals, based on atomic time standards that are accurate, allow the NetClock/2 to distribute consistent, legally traceable time throughout your system.
Outputs available from NetClock/2 include an RS-232 serial port, RS-485 data bus port, IRIG B or E and TTL, a 1 PPS frequency output, and an alarm output. The instrument is compatible with a wide range of equipment, including voice recorders, ANI/ALI, radio consoles, computer-aided dispatch systems, audible and visual time announcement devices, and others.
Other features include easy adaptability to standard rack mount, built-in battery backup, and high visibility front panel LED time display.
Technical Specifications
| Received Frequency | 60 kHz, NIST Station WWVB |
| Sensitivity | 0.4 microvolts rms into 50 ohms |
| Accuracy | Typical 1 Pulse-Per-Second (PPS): ±0.5 millisecond IRIG B/E AM and TTL: ±300 microseconds of on-time point RS-232 and RS-485: ASCII Time Codes ±3 milli-seconds. Leading edge of first character in data stream is on-time mark. |
| Input / Output Connectors and Switches | | RS-232 Serial Comm | DB9 Female | | RS-485 Once-per Second | DB9 Female | | Antenna | BNC | | IRIG B/E | BNC | | IRIG TTL | BNC | | PPS | BNC | | Alarm Output | Terminal Block | RS-232 and RS-485 ports can be set up to output time code data format 0, 1 or 2. Baud rates and 300 to 9600, 8N1. Contact Sales Department for full description of time code formats.
The two IRIG outputs are AM and TTL. They are configurable to format B at 1000 Hz, E at 100 Hz and can be set to operate with or without signature control. AM output is adjustable 0 to 10 V into 600 ohms. IRIG time codes follow Daylight Saving Time rule if enabled.
Alarm output, contact closure, for "Loss of Time Sync" and "Power Loss".
Set up Switches: Format, path delay, time zone, automatic Daylight Saving, baud rate, manual set disable, 12 or 24-hour display.
AGC (Automatic Gain Control) outputs on the rear panel are used during installation to aim the antenna, and monitor relative WWVB signal strength.
Front Panel: Selectable 12 or 24-hour red LED display (0.8"), displays Hours, Minutes, Seconds. Red/Green Status
Indicators: Antenna and cable OK; receiver lock to WWVB signal; accurate time sync to WWVB. |
| Power | 115/230 VAC, 50/60 Hz, 12 VA SmartWatch™, included in each clock, keeps time during power loss and resets display and data stream when power is restored. |
| Warranty | 5-year Warranty |
Physical & Environmental Specifications
| Size / Weight | 3"H x 7.8"W x 11"D / 4.75 lbs |
| Temperature | 0° to 50° C operating range -40° to 85° C storage range 95% relative humidity, non-condensing |
Antenna and Accessories
| 60 kHz Loop Antenna, Model 8219 | with mast and mounting clamps. Size: 10.0"L x 2.7"D; Operating temperature range -30 to +70°C |
| Preamplifier, Model 8207 | 60-kHz. Provides 40 dB of gain between antenna and receiver. Size 5.25L x 2.63W x 1.71H inches. Mounting pattern 4.75" x 1.75". Operating temperature 0° - 50°C. |
| Option 1 | Rack Mount for 19" EIA rack |
| TimeTap, Model 8179T | for time distribution. Includes 12 VDC power adapter. Order one for each RS-232 device.
Display Clocks, TimeView 230, Model 9175 or TimeView 400, Model 9177 |
| Antenna Accessories | Surge Suppressor, MP08455 (lightning protection). Antenna Flat Roof Mount, Model 8213. Antenna Cable, 50-ohm RG-58 coaxial cable, to user-specified length. CA01xxx, xxx = length in feet. (CA01100 = 100', CA01200 = 200') 1500' maximum. |
| Software | NetClock Time Manager - NTM5 to synchronize WIN 95/98/NT computers and Novell Servers. TimeSet-TS1 to synchronize TimeView Display Clocks from Win 95/98/NT or DOS computers. PresenTense - Complete Windows Network synchronization software for Win95/98/ME/NT/XP/2000/2003.
Ethernet Time Server, Model 9188: accurate time for intranet and enterprise networks.
TimeBurst, Model 8185: broadcast time to every agency in your community. |
| Complies with requirements in Part 15 of FCC rules for Class "A” Computing Devices. |
Ordering Information
| 1 | NetClock/2 Master Clock, Model 8182 |
| 1 | Model 8219 WWVB Antenna with mounting hardware |
| 1 | Model 8207 Preamplifier |